Compare test stations using equivalent products, test programs, limits and first-attempt definitions. An overall yield ranking can be misleading when stations process different product mixes. Show both the underlying cohorts and the amount of data before deciding that a station performs worse.

Key takeaways

  • Align product revision, test coverage, limits, units and time period.
  • Compare first attempts separately from repeat tests.
  • Use a common product mix only when the underlying groups are comparable.

Why the aggregate ranking can reverse

Consider this synthetic example. Product X is easier to pass than Product Y. Station A processes mostly Y, while Station B processes mostly X. All counts below refer to distinct units on their first attempt.

Product Station A passes / tested Station A yield Station B passes / tested Station B yield
X 98 / 100 98% 873 / 900 97%
Y 810 / 900 90% 89 / 100 89%
Combined 908 / 1,000 90.8% 962 / 1,000 96.2%

Station A has the higher observed yield for each product, yet the lower combined yield. The overall difference reflects the different mix. Using an illustrative common weighting of 50% X and 50% Y gives A 94% and B 93%. These standardized rates are comparison summaries, not the actual yields achieved by either station.

This table does not establish statistical significance or prove a station effect. Product revision, operating conditions and sampling uncertainty still need review.

Build a comparison contract

Before ranking stations, agree the fields that must match. At minimum, review product and hardware revision, test step identity, program version, specification and test limits, measurement units, route position, time window and attempt type. Different test names may describe the same measurement; identical names may conceal changed logic.

For each comparison, retain the original units and any documented conversion. Do not convert pass/fail outcomes into comparable measurements when the underlying coverage or limits differ. Keep changed programs in separate groups until engineering confirms equivalence.

Use the same denominator

Count first-attempt failures divided by first attempts for the defined cohort. Report retested units and later outcomes separately. If one site logs every attempt while another exports only the final result, their apparent yields are not directly comparable.

Show sample sizes next to percentages and avoid ranking small groups with unwarranted precision. Flag incomplete records and explain which units were excluded. A missing failure record is a data-quality issue, not a passing unit.

Move from ranking to investigation

  1. Find the shared cohorts. Compare products and revisions that both stations actually processed.
  2. Inspect the measurements. Look for shifts, spread, limit proximity and the specific failing steps.
  3. Check the context. Review fixture condition, calibration, maintenance, environment and upstream production differences.
  4. Validate the suspected mechanism. Use approved reference-unit or controlled comparison procedures where appropriate.

If there is no common product or qualified reference, say that the evidence does not support a direct station ranking. A model-based adjustment would require additional assumptions and validation; it should not be presented as an observed like-for-like result.

What should a cross-site report contain?

Include raw cohort counts, first-attempt rates, retest rates, exclusions and data-completeness notes. Add the exact program and limit revisions, the comparison period and the action owner. Keep the observed results separate from any standardized summary.

Test-station analytics helps frame these investigations. For teams working across external manufacturing partners, the electronics manufacturing services overview provides related context.

Put the checklist to work

Select one shared product and test revision before comparing stations. Book a demo to discuss the data and investigation workflow with QualityLine.